Welcome to PsychiatryAI.com: [PubMed] - Psychiatry AI Latest

Automating Quality Control in Cardiac MRI: AI for Discriminative Assessment of Planning and Movement Artefacts and Real-Time Reacquisition Guidance

Evidence

J Cardiovasc Magn Reson. 2024 Jul 28:101067. doi: 10.1016/j.jocmr.2024.101067. Online ahead of print.

ABSTRACT

BACKGROUND: Accurate measurements from cardiac magnetic resonance (CMR) images require precise positioning of scan planes and elimination of movement artefacts from arrhythmia or breathing. Unidentified or incorrectly managed artefacts degrade image quality, invalidate clinical measurements and decrease diagnostic confidence. Currently, radiographers must manually inspect each acquired image to confirm diagnostic quality and decide whether reacquisition or a change in sequences is warranted. We aimed to develop an artificial intelligence (AI) to provide continuous quality scores across different quality domains, and from these, determine whether cines are clinically adequate, require replanning, or warrant a change in protocol.

METHODS: A three-dimensional convolutional neural network was trained to predict cine quality graded on a continuous scale by a level 3 CMR expert, focusing separately on planning and movement artefacts. It incorporated four distinct output heads for the assessment of image quality in terms of: (a, b, c)2-, 3- and 4-chamber misplanning, and (d)long- and short-axis arrhythmia/breathing artefact. Back-propagation was selectively performed across these heads based on the labels present for each cine. Each image in the testing set was reported by four level 3 CMR experts, providing a consensus on clinical adequacy. The AI’s assessment of image quality and ability to identify images requiring replanning or sequence changes were evaluated with Spearman’s rho and the area under receiver operating characteristic (AUROC) respectively.

RESULTS: A total of 1940 cines across 1387 studies were included. On the test set of 383 cines, AI-judged image quality correlated strongly with expert judgement, with Spearman’s rho of 0.84, 0.84, 0.81 and 0.81 for 2-, 3- and 4-chamber planning quality and the extent of arrhythmia or breathing artefacts, respectively. The AI also showed high efficacy in flagging clinically inadequate cines (AUROC 0.88, 0.93, 0.93 and for identifying replanning of 2-, 3- and 4-chamber cines, and 0.90 for identifying movement artefacts).

CONCLUSION: AI can assess distinct domains of CMR cine quality and provide continuous quality scores that correlate closely with a consensus of experts. These ratings could be used to identify cases where reacquisition is warranted, and guide corrective actions to optimise image quality, including replanning, prospective gating, or real-time imaging.

PMID:39079601 | DOI:10.1016/j.jocmr.2024.101067

Document this CPD Copy URL Button

Google

Google Keep

LinkedIn Share Share on Linkedin

Estimated reading time: 6 minute(s)

Latest: Psychiatryai.com #RAISR4D Evidence

Cool Evidence: Engaging Young People and Students in Real-World Evidence

Real-Time Evidence Search [Psychiatry]

AI Research

Automating Quality Control in Cardiac MRI: AI for Discriminative Assessment of Planning and Movement Artefacts and Real-Time Reacquisition Guidance

Copy WordPress Title

🌐 90 Days

Evidence Blueprint

Automating Quality Control in Cardiac MRI: AI for Discriminative Assessment of Planning and Movement Artefacts and Real-Time Reacquisition Guidance

QR Code

☊ AI-Driven Related Evidence Nodes

(recent articles with at least 5 words in title)

More Evidence

Automating Quality Control in Cardiac MRI: AI for Discriminative Assessment of Planning and Movement Artefacts and Real-Time Reacquisition Guidance

🌐 365 Days

Floating Tab
close chatgpt icon
ChatGPT

Enter your request.

Psychiatry AI RAISR 4D System Psychiatry + Mental Health