Welcome to PsychiatryAI.com: [PubMed] - Psychiatry AI Latest

Modeling of Valve-in-Valve Transcatheter Aortic Valve Implantation after Aortic Root Replacement Using 3-Dimensional Artificial Intelligence Algorithm

Evidence

J Thorac Cardiovasc Surg. 2024 Jun 29:S0022-5223(24)00546-4. doi: 10.1016/j.jtcvs.2024.06.024. Online ahead of print.

ABSTRACT

OBJECTIVE: Aortic root replacement requires construction of a composite valve-graft and reimplantation of coronary arteries. This study assessed the feasibility of valve-in-valve transcatheter aortic valve implantation after aortic root replacement.

METHODS: A retrospective review was conducted on 74 consecutive patients who received a composite valve-graft at a single institution from 2019 to 2021. Forty patients had bioprosthetic valves with adequate postoperative gated computed tomographic angiography scans. Computational simulations of balloon and self-expanding transcatheter valve deployments were performed. The modeled coronary distances were compared to traditional, manually measured valve-to-coronary distances.

RESULTS: There was a statistically significant difference in the modeled versus manual measurements of valve to coronary distances were for all patients regardless of valve type or coronary artery analyzed (p <0. 05). Most patients are low risk for coronary obstruction per three-dimensional modeling including those with a valve-to-coronary distance <4 millimeters. Only one patient (2.5%) was at risk for coronary obstruction for the left coronary artery using a ballonvalve. No other valve combination was considered high risk of coronary obstruction. Five patients (12.5%) were at risk for possible valve stent deformation at the outflow, due to angulation at the graft anastomosis.

CONCLUSIONS: Following aortic root replacement, all patients were candidates for Valve-in-Valve using one or both types of transcatheter heart valves. Self-expanding valves may be at higher risk for stent frame deformation at graft anastomotic lines and balloon-expandable valves may be at higher risk of coronary obstruction.

PMID:38950772 | DOI:10.1016/j.jtcvs.2024.06.024

Document this CPD Copy URL Button

Google

Google Keep

LinkedIn Share Share on Linkedin

Estimated reading time: 5 minute(s)

Latest: Psychiatryai.com #RAISR4D Evidence

Cool Evidence: Engaging Young People and Students in Real-World Evidence

Real-Time Evidence Search [Psychiatry]

AI Research

Modeling of Valve-in-Valve Transcatheter Aortic Valve Implantation after Aortic Root Replacement Using 3-Dimensional Artificial Intelligence Algorithm

Copy WordPress Title

🌐 90 Days

Evidence Blueprint

Modeling of Valve-in-Valve Transcatheter Aortic Valve Implantation after Aortic Root Replacement Using 3-Dimensional Artificial Intelligence Algorithm

QR Code

☊ AI-Driven Related Evidence Nodes

(recent articles with at least 5 words in title)

More Evidence

Modeling of Valve-in-Valve Transcatheter Aortic Valve Implantation after Aortic Root Replacement Using 3-Dimensional Artificial Intelligence Algorithm

🌐 365 Days

Floating Tab
close chatgpt icon
ChatGPT

Enter your request.

Psychiatry AI RAISR 4D System Psychiatry + Mental Health